CxFmsAlarmLogCtrl Example

Use the CxFmsAlarmLogCtrl object to display and manipulate an ActiveX CygNet FMS Alarm Control in a CygNet Studio screen environment.

CygNet FMS Alarm Control
CygNet FMS Alarm Control Example

To see an example FMS Alarm Log control implemented in a pre-designed screen, open the FMS Alarm Ctrl.csf file found in the APPS SCREXAMP or in the CygNet\Clients\CStudio\Screens\Examples folder.

CygNet Studio Screen Script: FMS Alarm Ctrl.csf

Copy
CxFmsAlarmLogCtrl Example
Sub btnApply_EventClick()
Dim This : Set This = btnApply
    FmsAlarm.SessionNodeTag = editSessionNode.Text
    FmsAlarm.SessionBeginDate = editStartDate.Text
    FmsAlarm.SessionEndDate = editEndDate.Text
    FmsAlarm.SessionDateFormat = cboDateFormat.Selection
    FmsAlarm.PITDateTime = editPIT.Text
    FmsAlarm.UsePIT = checkUsePIT.Check
    FmsAlarm.Apply True
End Sub 
 
Sub btnCancel_EventClick()
Dim This : Set This = btnCancel
    FmsAlarm.Cancel
End Sub 
 
Sub cboDateFormat_EventChange()
Dim This : Set This = cboDateFormat
    FmsAlarm.SessionDateFormat = this.Selection
End Sub 
 
Sub checkUsePIT_EventChange()
Dim This : Set This = checkUsePIT
    FmsAlarm.UsePIT = this.Check
    editPIT.Enable this.Check
End Sub 
 
Sub TheView_EventInitialize()
Dim This : Set This = TheView
    editSessionNode.Text = FmsAlarm.SessionNodeTag
     
    editStartDate.Text = FmsAlarm.SessionBeginDate
    editEndDate.Text = FmsAlarm.SessionEndDate
    cboDateFormat.AddString "Device"
    cboDateFormat.AddString "Contract"
    cboDateFormat.AddString "Local"
    cboDateFormat.Selection = FmsAlarm.SessionDateFormat
     
    checkUsePIT.Check = FmsAlarm.UsePIT
    editPIT.Text = FmsAlarm.PITDateTime
    editPIT.Enable = FmsAlarm.UsePIT
End Sub

Back to top